default image
High-pass test experimental device for three-channel optical fiber spectrometer
High-throughput material fluorescence testing, 54 samples in 30 minutes, accelerating material development.
Type
Equipment
Tags
Other
Optical technology and instruments
Fluorescence high-flux measurement
Fiber spectrometer
Solution maturity
Early adoption / Process verification
Cooperation methods
Other
Applicable industry
Scientific research and technology services
Applications
Material research and development
Key innovations
The innovation lies in high-throughput automated multi-sample fluorescence testing, which significantly improves material screening efficiency and accelerates the research and development process.
Potential economic benefits
Through high-throughput and automated testing, this product significantly shortens the material development cycle, reduces labor costs, greatly improves testing efficiency, accelerates the commercialization of new materials, and brings significant economic returns.
Potential climate benefits
This equipment accelerates the research and development of luminescent materials and new energy materials, promotes the popularization of energy-saving products and clean energy technologies, and indirectly achieves carbon emission reduction by improving energy efficiency and replacing fossil energy.
Solution supplier
View more
Shanghai Institute of Silicate, Chinese Academy of Sciences
Shanghai Institute of Silicate, Chinese Academy of Sciences
The Shanghai Institute of Silicate, Chinese Academy of Sciences, focuses on the research of advanced inorganic materials and supports high-tech industries and major national needs.
Shanghai,China
Solution details

1. application field

High-throughput testing of fluorescence properties of powders, films, bulk and other materials

2. technical characteristics

The fluorescence properties of three samples can be measured simultaneously by moving the position of the sample stage in real time. When the triplets of samples are tested, the sample stage moving unit automatically moves the sample stage to a new position, and under program control, each sample in the sample library is automatically traversed spectral testing.

3. performance Index

1) Monitoring wavelength 300-1000nm;

2) Excitation wavelength 254-1060nm;

3)Testing 54 samples takes approximately 30 minutes

4. current state

There is currently one such equipment in the laboratory

Last updated
10:50:42, Nov 04, 2025